Skip to content

ControlOpV2

Overview

Control signal operations module

Discussion

The module computes control operations (e.g. control signals from CAN) which are simple arithmetic operations using two input values. A single row is devoted to each operation:

Column 1 specifies what operation should be performed:

op=0, CONST 0 (out = 0)

op=1, CONST 1 (out = 1)

op=2, Pass through (out = in1)

op=3, Sum (out = in1 + in2).

op=4, Diff (out = in1 - in2)

op=5, Average (out = (in1 + in2) / 2)

op=6, Time Derivative (out = (in1[n] - in1[n-1]) * SR)

op=7, Multiplication (out = in1 * in2)

op=8, Division (out = in1 / in2)

op=9, dB to linear (out = undb20(in1))

op=10, Max (in1, in2)

op=11, Min (in1, in2)

op=12, Equal One Pass 2 (if (in1 == 1) --> out = in2, else out = 1)

op=13, Not Equal One Pass 2 (if (in1 != 1) --> out = in2, else out = 1)

op=14, Greater Than, (if (in1 >= in2) --> out = 1, else out = 0)

op=15, Boolean Invert (if (in1 < 0.5) --> out = 1, else out = 0)

op=16, FlipFlop1 - 1 for in1 = 1 until in2 = 1, else output 0

op=17, FlipFlop2 - 1 if in1 = 1 for sample count in in2, else output 0

op=18, Absolute (out = abs(in1))

Column 2 contains the channel index of the first input argument (0-based). Column 3 contains the channel index of the second input argument (0-based).

If an index is out of range or the op is out of range then the module outputs 0 for that operation.

This module supports only control data where block size is 1.

Note: op=18 (ABS) was introduced in SND module pack version 1.0.15. Targets running an older SND version will silently output 0 for this operation.

Module Pack

awe-mod-dspc-snd

ClassID

classID = 41834

Type Definition

typedef struct _ModuleControlOpV2
{
ModuleInstanceDescriptor instance;            // Common Audio Weaver module instance structure
INT32 numOps;                                 // Number of operations to be computed
INT32 updateActive;                           // Specifies whether the configuration is updating (=1) or fixed (=0).
INT32* opType;                                // Controls the operations (opType). One row per operation.
INT32* chIdx1;                                // Controls the operations (channel index 1). One row per operation.
INT32* chIdx2;                                // Controls the operations (channel index 2). One row per operation.
FLOAT32* lastValue;                           // Previous sample value on all input channels
INT32* firstBlock;                            // Array of flags set on first block of each channel before lastValue is valid
INT32* triggerPulse1;                         // Array of flags set on in operation OP_FLIPFLOP1 to trigger pulse output
INT32* triggerPulse2;                         // Array of flags set on in operation OP_FLIPFLOP2 to trigger pulse output
INT32* prevTriggerState;                      // Array of flags set on in OP_FLIPFLOP2 to trigger pulse output
INT32* outPulseCnt;                           // Array of  pulse high period count in samples for triggerPulse2
} ModuleControlOpV2Class;

Variables

Properties

Name Type Usage isHidden Default Value Range Units
numOps int const 0 1 1:1:256
updateActive int parameter 1 1 0:1
opType int* parameter 0 [1 x 1] Unrestricted
chIdx1 int* parameter 0 [1 x 1] Unrestricted
chIdx2 int* parameter 0 [1 x 1] Unrestricted
lastValue float* state 1 [1 x 1] Unrestricted
firstBlock int* state 1 [1 x 1] Unrestricted
triggerPulse1 int* state 1 [1 x 1] Unrestricted
triggerPulse2 int* state 1 [1 x 1] Unrestricted
prevTriggerState int* state 1 [1 x 1] Unrestricted
outPulseCnt int* state 1 [1 x 1] Unrestricted

Pins

Input Pins

Name in
Description Input signal
Data type float
Channel range Unrestricted
Block size range 1
Sample rate range Unrestricted
Complex support Real

Output Pins

Name out
Description Output signal
Data Type float

Matlab Usage

File Name: control_op_v2_module.m 
 Performs various arithmetic operations that are typically applied 
 to CAN control inputs. The opreation is applied to the two inputs,  
 which can be also multichannel. The second argument specifies how many  
 operations shall be performed. Each result is placed on a separate  
 output channel.   
 Arguments: 
    NAME - name of the module. 
    NUMOPS - number of operations to compute.  By default equals 1. 

Copyright (c) 2026 DSP Concepts, Inc.